Bristol BSAP/IBP Error Codes

Error code
(Decimal)
Error code
(Hex)
Meaning
0000 0x0 No Error
0101 0x65 Invalid or Null String Memory Address Parameter
0102 0x66 No Message or Data Type Found in Tag Address
0103 0x67 Invalid Message Type in Address
0104 0x68 Calculated and Received CRC do not Match
0107 0x6b Local Node Response Timeout
0108 0x6c Unknown Serial Number Received
0109 0x6d NAK Message Received, RTU Buffers Full
0110 0x6e Poll Time has been Exceeded
0111 0x6f Invalid Data Type Received
0112 0x70 Data Read Timeout
0113 0x71 Invalid Data Type Specified
0114 0x72 Too Many Addresses for a Single Message
0116 0x74 Name not Found or Message Buffer Byte Count Exceeded
0117 0x75 Analog Value Found in Packed Logic Processing
0118 0x76 No Match Found
0119 0x77 ACCOL Version Number did not Match
0120 0x78 Invalid Database Function Requested
0121 0x79 Attempted to Write to Read Only Area
0122 0x7a Invalid Identifier, Name or MSD Address
0123 0x7b Security Violation
0124 0x7c Attempted to Write to Manually Inhibited Signal
0125 0x7d Invalid Write Attempted
0126 0x7e Incomplete RDB Request
0127 0x7f No Match for Indicated Signal Name
0128 0x80 Data Write Timeout
0129 0x81 Invalid header size
0136 0x88 RBE is not defined
0137 0x89 RBE Cannot Allocate Dedicated Buffers
0138 0x8a RBE Cannot Queue IO Requests
0139 0x8b RBE Bad Message
0140 0x8c RBE Bad Function Code
0141 0x8d RBE Bad Sub-Function Code
0142 0x8e RBE Bad Scan Period
0143 0x8f RBE Bad Stop Transmit Limit
0144 0x90 RBE Bad Report Format
0145 0x91 RBE Bad Parameter - Number of Entries
0146 0x92 RBE Bad Parameter - Op Code
0147 0x93 RBE Bad Entry in Act/DAct Request
0148 0x94 RBE Bad RSN in Demand Request
0149 0x95 RBE Bad RSN in Report Ack
0150 0x96 RBE Post Switchover Error Detected
0151 0x97 RBE Bad Port
0152 0x98 RBE Manager Response Timeout
0153 0x99 No Network Master Defined
0154 0x9a Unknown Error Code
0155 0x9b BSAP Receive Message Echo Timeout
0156 0x9c BSAP Receive Message Header Timeout
0157 0x9d BSAP Receive Message Address Mismatch
0158 0x9e BSAP Response Message Serial Number Mismatch
0159 0x9f File Read - Attempting To Read Bad File #
0160 0xa0 File Read - Attempting To Read Bad File Record #
0161 0xa1 Unknown Error Returned from RTU in SES
0162 0xa2 BSAP Attempting to send Unknown Message Type
0163 0xa3 BSAP No Acknowledge of sent Up Acknowledge
0164 0xa4 Level 1 Node Is Offline, Cannot Send Message
0165 0xa5 No MSD Addresses Found in RTU for RBE Names
0166 0xa6 Attempting To Send NRT to Non-Level 1 Device
0168 0xa8 Audit Read -EAUDIT Process Not Defined In Device
0169 0xa9 Audit Read - Security Code Did Not Match
0170 0xaa Audit Read - Delete of Records Not Performed
0171 0xab Attempting To Read Bad File Date
0172 0xac File Read - Memory Allocation Error
0173 0xad File Read - Missing File Definition
0174 0xae File Read - Error In File Definition
0175 0xaf Bad Write Address
0176 0xb0 Polling Paused
0177 0xb1 IBP Data Link Not Ready
0178 0xb2 Incomplete IBP Message Received
0179 0xb3 Unknown Error Returned from RTU
0180 0xb4 Stuck Reading Audit Log
0181 0xb5 NAK Limit Reached for RTU
0182 0xb6 EBSAP Group Number Did Not Match
0183 0xb7 Unknown Error Returned from RTU in PES
0184 0xb8 Request Format Is Incorrect
0185 0xb9 Invalid File Number or Name
0186 0xba Invalid Record Number or Name
0187 0xbb Audit File Not Defined
0188 0xbc Request Format Incorrect
0189 0xbd Date Request For Non Historical Archive
0190 0xbe Expanded Group Not Defined
0191 0xbf Invalid Port Number (From RTU)
0192 0xc0 Port Number Is Unused (From RTU)
0193 0xc1 Port Error (From RTU)
0194 0xc2 Security Code Not Defined In Running ACCOL Load
0195 0xc3 Not All Elements Fin In Response Buffer (More To Go)
0196 0xc4 Invalid Array Type
0197 0xc5 Error In Request Group
0198 0xc6 Not All Elements Fit In The Response And There Is An Error In A Group
0199 0xc7 Invalid Array Number (Not In Load)
0200 0xc8 Invalid Row Or Column
0201 0xc9 Invalid Custom Interface Table
0202 0xca Unsupported Function
0203 0xcb Unsupported Sub-Function
0204 0xcc Error In Reset Request
0205 0xcd Error In Date/time Request
0206 0xce Unknown PES Error Code
0207 0xcf Number Of Records In response Less Than Requested
0208 0xd0 Unknown PES SES Combination
0209 0xd1 Level 1 Node Congestion
0210 0xd2 Read Signals Timeout
0211 0xd3 Timed Out Sending Message
1001 0x3e9 Port Not Defined
1002 0x3ea Port Failed To Connect
1003 0x3eb Port Lost Connection
1004 0x3ec Serial Port Settings Out of Range
1005 0x3ed Serial Port Already In Use or Not Available
1006 0x3ee Serial Port Access Denied
1007 0x3ef Serial Port General Failure
1008 0x3f0 Serial Port Invalid Parameter
1009 0x3f1 Port Not Connected
1010 0x3f2 Port Unknown Error