Omron FINS Error Codes
| Error code (Decimal) |
Error code (Hex) |
Meaning |
|---|---|---|
| 00 | 0x0 | No Error |
| 01 | 0x1 | Invalid Memory Address Parameter |
| 02 | 0x2 | Invalid or Illegal Command Param |
| 03 | 0x3 | Response SID did not match |
| 04 | 0x4 | NSB did not respond to send req |
| 05 | 0x5 | Timed Out - No Response |
| 06 | 0x6 | Timed Out Waiting For Response |
| 07 | 0x7 | Bad Received CRC |
| 08 | 0x8 | Unmatched Message IDs |
| 09 | 0x9 | Unmatched Command/Response |
| 10 | 0xa | Unknown Error |
| 11 | 0xb | Network Address Out Of Range |
| 12 | 0xc | Node Address Out Of Range |
| 13 | 0xd | Unit Address Out Of Range |
| 14 | 0xe | Invalid Address Parameter |
| 15 | 0xf | Timed Out waiting for echo |
| 16 | 0x10 | Bad Received FCS |
| 17 | 0x11 | Response from different Host Link Unit |
| 18 | 0x12 | No Valid Response Code |
| 19 | 0x13 | No FINS Response Packet |
| 20 | 0x14 | Unknown Error Code |
| 21 | 0x15 | Local Node not part of Network |
| 22 | 0x16 | Token Timeout, Node # too High |
| 23 | 0x17 | Number of Transmit Retries Exceeded |
| 24 | 0x18 | Max # of Frames Exceeded |
| 25 | 0x19 | Node # Setting Error |
| 26 | 0x1a | Node # Duplication Error |
| 27 | 0x1b | Dest Node not part of Network |
| 28 | 0x1c | No Node with Node # Specified |
| 29 | 0x1d | Third Node not part of Network |
| 30 | 0x1e | Busy Error, Dest Node Busy |
| 31 | 0x1f | Response Timeout, Noise or Watchdog |
| 32 | 0x20 | Error in Comm Controller |
| 33 | 0x21 | PLC Error in Dest Node |
| 35 | 0x23 | Undefined Command Used |
| 36 | 0x24 | Cannot Process Command |
| 37 | 0x25 | Routing Error |
| 38 | 0x26 | Command is too Long |
| 39 | 0x27 | Command is too Short |
| 40 | 0x28 | Specified Data Items != Actual |
| 41 | 0x29 | Incorrect Command Format |
| 42 | 0x2a | Incorrect Header |
| 43 | 0x2b | Memory Area Code Error |
| 44 | 0x2c | Access Size Specified is Wrong |
| 45 | 0x2d | First Address is Inaccessible |
| 46 | 0x2e | Address Range Exceeded |
| 47 | 0x2f | Unknown Error Code |
| 48 | 0x30 | Non-existent Program # Specified |
| 49 | 0x31 | Unknown Error Code |
| 50 | 0x32 | Unknown Error Code |
| 51 | 0x33 | Data Size in Command is Wrong |
| 52 | 0x34 | Unknown Error Code |
| 53 | 0x35 | Response Block too Long |
| 54 | 0x36 | Incorrect Parameter Code |
| 55 | 0x37 | Program Area Protected |
| 56 | 0x38 | Registered Table Error |
| 57 | 0x39 | Area Read-Only or Write Protected |
| 59 | 0x3b | Mode is Wrong |
| 60 | 0x3c | Mode is Wrong (Running) |
| 61 | 0x3d | PLC is in Program Mode |
| 62 | 0x3e | PLC is in Debug Mode |
| 63 | 0x3f | PLC is in Monitor Mode |
| 64 | 0x40 | PLC is in Run Mode |
| 65 | 0x41 | Specified Node is not Control Node |
| 66 | 0x42 | Specified Memory does not Exist |
| 67 | 0x43 | No Clock Exists |
| 68 | 0x44 | Data Link Table Error |
| 69 | 0x45 | Unit Error |
| 70 | 0x46 | Command Error |
| 71 | 0x47 | Destination Address Setting Error |
| 72 | 0x48 | No Routing Tables |
| 73 | 0x49 | Routing Table Error |
| 74 | 0x4a | Too Many Relays |
| 75 | 0x4b | The Header is not FINS |
| 76 | 0x4c | The Data Length is too Long |
| 77 | 0x4d | The Command is not Supported |
| 80 | 0x50 | Timed Out waiting for Port Semaphore |
| 94 | 0x5e | All Connections are in Use |
| 95 | 0x5f | The Specified Node is Already Connected |
| 96 | 0x60 | Attempt to Access Protected Node from Unspecified IP |
| 97 | 0x61 | The Client FINS Node Address is OOR |
| 98 | 0x62 | Same FINS Node Address is being used by Client and Server |
| 99 | 0x63 | No Node Addresses are Available to Allocate |