Tag Groups
VTScada has tag groups that are used to organize the standard tag types into collections based on their value, capabilities, or other characteristics. Some of the tag types belong to multiple groups based on shared characteristics.
The tag groups enable selection of a specific tag type in a tag-associated drop-down list. For example, when creating a new driver tag type to be associated with an Analog Input or Digital Input tag, clicking the tag browser button to the right of the I/O Device field opens a group dialog from which you can select the type of driver tag you wish to create.

The analogs group assembles those tags that read or write analog (continuous floating point) values to a device.
The group is composed of the following members:
I/O and Calculations - Analog, Discrete, Numeric Calculation | |
Analog Control tags |
Analog Input tags |
Analog Output tags |
Analog Status tags |
Counter |
Data Flow Pulse input |
Calculation | Selector Switch |
Rate of Change |
Totalizer |

The container group is composed of those tags that can have contributors. (An example of a container/contributor relationship might be at a power generation station, where the container tag (also referred to as an owner tag) would calculate the overall power output for the entire station based on the value of its many contributor tags.)
The container group is composed of the following members:
Analog Statistics |
Context |
Data Flow RTU |
Digital Statistics |
Grundfos Dedicated Controls |
MPE Duplexer Station |
MPE SC Station |
MultiSmart |
Polling Driver |
Subordinate |

The digitals group assembles those tags that read or write digital (discrete) values to an I/O device.
The group is composed of the following members:
I/O and Calculations - Analog, Discrete, Numeric Calculation |
|
Alarm |
Alarm priority |
Data Flow RTU |
Digital control |
Digital input |
Digital output |
Digital status |
Network status |
Polling driver |
Pump status |
PLC Alarm | Selector Switch |
Roster |
Trigger |

The drivers group consists of tags that are used to provide an interface to physical I/O devices or to Windows system features, such as Dynamic Data Exchange.
The group is composed of the following members:
ABB TotalFlow | BACnet | Bristol BSAP/IBP Driver |
Bristol BSAP/IBP Network | CalAmp Diagnostic | Campbell Scientific Array |
Campbell Scientific PakBus | CATM5X | CSV |
Data Flow System RTU | DDE Client | DNP3 |
Driver Multiplexer | Enron Modbus | Fisher ROC |
GE Series 90 | Honeywell Mercury | IEC 60870-5-104 |
JSON/XML | Koyo DirectNET | MDS Diagnostic |
Mitsubishi | Modicon - See Modbus | Modbus Compatible Device |
Motorola ACE | MQTT Client | NMEA 0183 |
Omron FINS | Omron Host Link | OPC Client (and, OPC Server Setup) |
OPC UA Client | Polling | Rockwell (Allen Bradley Devices) |
Siemens S7 | SNMP Managed Device | SQL Data Query |
Tesco Data Express Plus | TI505 | Toyopuc |
Transaction Logger | Veeder Root | Workstation Status |

The VTScada loggers group consists of tags that have a numeric value, and that can have their data logged to disk for data examination and analysis, and plotting on the Historical Data Viewer page by having a Historian tag associated with them, either directly or via a Logger tag.
In this case, it is easier to list the tags that are NOT members:
Alarm Database | Alarm Priority |
Context |
Font |
Grundfos Dedicated Controls | Historian |
Logger |
Menu Item |
MPE Station | MPE Duplexer Station |
Multismart Station | Realm Display Setup |
Style Settings | Subordinate Application |
Workstation Driver |

The numeric group is composed of tags that have a numeric value:
All drivers | All ports |
Alarm |
Alarm Status |
Analog Control |
Analog Input |
Analog Output |
Analog Status |
Analog Statistics |
Calculation |
I/O and Calculations |
Counter |
Deadband Control |
Digital Control |
Digital Input |
Digital Output |
Digital Status |
Digital Statistics |
Function |
History Statistics |
Modem |
Data Flow Pulse input |
Pump Status |
Rate of Change |
Roster |
Script |
Selector Switch |
SMS Appliance |
SQL Logger |
SQL Query |
Totalizer |
Trigger |

I/O and Calculations

The Trenders group consists of tags whose value can be plotted on the Historical Data Viewer page. The tags composing the Trenders group are:
All drivers | I/O and Calculations tag |
All ports |
Alarm Status |
Analog Control |
Analog Input |
Analog Output |
Analog Status |
Calculation |
Counter |
Deadband control |
Digital control |
Digital input |
Digital output |
Digital status |
Function |
History Statistics |
Notebook |
Pump status |
Rate of Change |
Script |
Selector Switch |
String I/O |
Totalizer |
Trigger |
When Trenders is selected in the Tag Browser's Types drop-down list, and the New button is clicked, the Trenders Group dialog will open, enabling you to select the type of tag you wish to create.
To create a new tag, select the radio button corresponding to the type of tag you wish to create, and then click OK. A new tag properties folder associated with the selected tag type will open for configuration.